MASDOM INC.
products & services
MASDOM INC.

Home / Products and Services / Noise Control / Enclosures /

Enclosures


ImagePANEL SPECIFICATIONS

  • 4" Nominal Thickness
  • Min. 18 Gauge galvanized steel outer casing
  • Min. 22 Gauge galvanized perforated steel facing sheet
  • Non-hygroscopic, vermin proof,incombustable, thermal filler material
  • For people
  • For machines

    TYPICAL APPLICATIONS

  • In plant offices
  • Machinery Enclosures
  • Noise Barriers
  • Testing Control Rooms
  • Rest Areas
  • Sound Laboratories

    SOUND ABSORPTION COOEFFICIENTS FOR BASIC SOUND SOAKER PANELS

    Octave Band Centre
    Frequency Hz 125 250 500 1000 2000 5000
    Absorption Coefficient 0.70 1.10 1.11 1.04 1.02 0.96
    Thermal Transmittance (U Valve) of 0.07 BTU/Sq.Ft./Hr./°F